FRP Round Cooling Tower Used For Cooling Effect
2021-06-01 14:40FRP Round Cooling Tower Used For Cooling Effect
Nothing beats the power of an excellent frp cooling tower. We are here to offer our clients with the best FPR square cooling tower to meets all their needs
We are an FPR cooling tower manufacturer who engages in the manufacturing and supplying of the best cooling towers in the market. Our goal is to offer equipment that can enhance power, water and space saving to the users. The towers come with fixed headers and splash noozles which help in distributing water over the fills.
The tower is made of pure high-grade fibreglass reinforced resin, which makes it durable and reliable regardless of the weather condition. The demanding users of this equipment are; diesel engine, process coolers, foam, leather, frozen series, and industrial cooling water among other uses.
FPR Round /Square Cooling Tower Parts
The cooling tower parts of FRP square cooling tower are:
Cast aluminium fan
These gravity fans are meant to help in the displacement of a high volume of air while they are light.
PVC fills
This PVC fill aims to help in enhancing heat transfer for maximum cooling.
Splash nozzles
The FPR square cooling tower comes with spray nozzles which help in hot water distribution in the cooling tower.
Motor
The cooling tower motor is meant for driving the fan
FRP Round Cooling Tower | ||||||
Medol | NominalFlow(m3/h) | AirVolume(CMM) | Motor(kW) | (16M)NoiseLevel(dBA) | DryWeigh(Kg) | WetWeigh(Kg) |
8T | 6.23 | 70 | 0.18 | 45 | 46 | 190 |
10T | 7.81 | 85 | 0.18 | 46 | 49 | 199 |
15T | 11.7 | 140 | 0.37 | 47 | 60 | 298 |
20T | 15.62 | 160 | 0.55 | 48 | 80 | 320 |
25T | 19.51 | 200 | 0.75 | 49 | 110 | 540 |
30T | 23.4 | 230 | 0.75 | 50 | 135 | 550 |
40T | 31.21 | 280 | 1.5 | 52 | 150 | 590 |
50T | 39.24 | 330 | 1.5 | 53 | 210 | 1050 |
60T | 46.8 | 420 | 1.5 | 53.5 | 260 | 1280 |
70T | 54.68 | 450 | 1.5 | 54 | 290 | 1600 |
80T | 62.5 | 630 | 2.2 | 54 | 1410 | 550 |
90T | 70.31 | 630 | 2.2 | 54 | 350 | 1650 |
100T | 78.12 | 700 | 3 | 54.5 | 1540 | 580 |
125T | 97.56 | 830 | 3 | 55 | 410 | 1700 |
150T | 117 | 950 | 3 | 55 | 600 | 1850 |
175T | 136.8 | 1150 | 3.75 | 55 | 890 | 2010 |
200T | 156.2 | 1250 | 3.75 | 55.0 | 920 | 2100 |
225T | 175.5 | 1500 | 5.5 | 52 | 1100 | 2870 |
250T | 195.12 | 1750 | 5.5 | 53 | 1200 | 2950 |
300T | 234 | 2000 | 7.5 | 53.5 | 1820 | 4050 |
350T | 273.24 | 2000 | 7.5 | 54 | 1890 | 4100 |
400T | 312.12 | 2400 | 11 | 54.5 | 2920 | 5900 |
500T | 392.4 | 2600 | 15 | 55 | 3010 | 5950 |
600T | 468 | 3750 | 15 | 56 | 4050 | 9450 |
700T | 547.2 | 3750 | 18.5 | 58.0. | 4180 | 9600 |
800T | 626.4. | 5000 | 22 | 59 | 4900 | 12100 |
1000T | 781.2 | 5400 | 22 | 59.5 | 5000 | 12300 |
Designparameters:Inlet water temperature--T1=37-40ºC outlet water temperature-.T2=32ºC Wet bulb temperature-WBT=27ºC Water temperature drop--Ts=5-8ºC Atmospheric pressure.P=99400Pa |
FRP Square Cooling Tower | ||||||||||||
Model | Cell | DIMENSIONS | Fan (mm) | Motor (mm) | pressure kPa | Weight (KG) | Noise (16m) | DN1 | DN2 | |||
A | B | H | ||||||||||
Standard Model | LATINO-80 | 80-C1 | 2280 | 2280 | 3535 | 1500 | 2.2 | 37 | 740 | 47.0 | 150 | 200 |
LATINO-100 | 100-C1 | 2530 | 2530 | 3655 | 1800 | 4.0 | 38 | 1020 | 48.0 | 150 | 200 | |
LATINO-125 | 125-C1 | 2830 | 2830 | 3785 | 1800 | 4.0 | 38 | 1270 | 49.0 | 150 | 200 | |
LATINO-150 | 150-C1 | 3080 | 3080 | 3860 | 2000 | 4.0 | 39 | 1530 | 50.0 | 150 | 200 | |
LATINO-175 | 175-C1 | 3330 | 3330 | 4060 | 2400 | 5.5 | 40 | 1840 | 51.0 | 150 | 200 | |
LATINO-200 | 200-C1 | 3530 | 3530 | 4150 | 2800 | 7.5 | 42 | 2040 | 52.0 | 200 | 250 | |
LATINO-225 | 225-C1 | 3730 | 3730 | 4220 | 2800 | 7.5 | 43 | 2400 | 53.5 | 200 | 250 | |
LATINO-250 | 250-C1 | 3930 | 3930 | 4495 | 2800 | 7.5 | 44 | 2398 | 54.5 | 200 | 250 | |
LATINO-300 | 300-C1 | 4330 | 4330 | 4765 | 3400 | 11 | 45 | 3760 | 55.0 | 250 | 300 | |
LATINO-400 | 400-C1 | 4980 | 4980 | 5315 | 4200 | 15 | 49 | 5800 | 57.5 | 250 | 300 | |
LATINO-500 | 500-C1 | 5580 | 5580 | 5685 | 4600 | 18.5 | 50 | 6480 | 58.5 | 300 | 350 | |
LATINO-600 | 600-C1 | 6080 | 6080 | 5825 | 4600 | 22 | 52 | 7760 | 60.5 | 300 | 350 | |
LATINO-650 | 225-C3 | 3730 | 11030 | 4220 | 2800 | 7.5x3 | 43 | 7220 | 61.0 | 200x3 | 250x3 | |
LATINO-700 | 175-C4 | 3330 | 13080 | 4060 | 2400 | 5.5x4 | 40 | 7360 | 61.5 | 150x4 | 200x4 | |
LATINO-800 | 200-C4 | 3530 | 13880 | 4150 | 2800 | 7.5x4 | 42 | 8180 | 62.0 | 200x4 | 250x4 | |
LATINO-900 | 225-C4 | 3730 | 14680 | 4220 | 2800 | 7.5x4 | 43 | 9630 | 62.5 | 200x4 | 250x4 | |
LATINO-1000 | 200-C5 | 3530 | 17330 | 4150 | 2800 | 7.5x5 | 42 | 10230 | 63.0 | 200x5 | 250x5 | |
LATINO-1100 | 225-C5 | 3730 | 18330 | 4220 | 2800 | 7.5x5 | 43 | 12000 | 63.5 | 200x5 | 250x5 | |
LATINO-1250 | 250-C5 | 3930 | 19330 | 4495 | 2800 | 7.5x5 | 44 | 11990 | 64.0 | 200x5 | 250x5 | |
LATINO-1500 | 300-C5 | 4330 | 21330 | 4765 | 3400 | 11x5 | 45 | 18800 | 64.5 | 250x5 | 300x5 | |
Moderate temprature Model | LATINO II-80 | 80-C1 | 2280 | 2280 | 4035 | 1500 | 3.0 | 42 | 1140 | 56.0 | 150 | 200 |
LATINO II-100 | 100-C1 | 2530 | 2530 | 4155 | 1800 | 4.0 | 43 | 1330 | 57.0 | 150 | 200 | |
LATINO II-125 | 125-C1 | 2830 | 2830 | 4285 | 1800 | 4.0 | 43 | 1620 | 58.0 | 150 | 200 | |
LATINO II-150 | 150-C1 | 3080 | 3080 | 4360 | 2000 | 5.5 | 44 | 1880 | 59.0 | 150 | 200 | |
LATINO II-175 | 175-C1 | 3330 | 3330 | 4560 | 2400 | 7.5 | 45 | 2380 | 60.0 | 150 | 200 | |
LATINO II-200 | 200-C1 | 3530 | 3530 | 4650 | 2800 | 7.5 | 47 | 2940 | 61.0 | 200 | 250 | |
LATINO II-225 | 225-C1 | 3730 | 3730 | 4720 | 2800 | 7.5 | 48 | 3150 | 62.0 | 200 | 250 | |
LATINO II-250 | 250-C1 | 3930 | 3930 | 4995 | 2800 | 7.5 | 49 | 3450 | 63.0 | 200 | 250 | |
LATINO II-300 | 300-C1 | 4330 | 4330 | 5265 | 3400 | 11 | 50 | 4160 | 63.5 | 250 | 300 | |
LATINO II-400 | 400-C1 | 4980 | 4980 | 5815 | 4200 | 15 | 54 | 6350 | 64.5 | 250 | 300 | |
LATINO II-500 | 500-C1 | 5580 | 5580 | 6185 | 4600 | 18.5 | 55 | 7180 | 65.5 | 300 | 350 | |
LATINO II-600 | 600-C1 | 6080 | 6080 | 6325 | 4600 | 22 | 57 | 9820 | 65.5 | 300 | 350 |
Components Instruction
Drift Eliminator
Air Inlet Louver
Distribution Nozzles
Steel Structure
Sea Water Solution
LATINO cooling tower also provide special solution for sea water application which is suite for sea side industrial project will use sea water as cooling media. Please contact your related sales manager for more details.
Product Show
LATINO has an experienced team in quality and project implement to support the purchasing activities of overseas customers;The company's main products are cooling tower parts, such as Film Fill, drift eliminator and spray system, UPVC distribution pipes, FPR winding splash pipe, FRP profile parts,FRP gratings, Fan stack, band & clamp, etc.; Our product are approved by CTI and we have our own patent .
Our Company
Tianjin LATINO Environmental Technology Co., Ltd. are on the base of high quality, good service, we win good reputation in the industry. We help our customers better to get cooling tower products from China.We specializes in manufacturing various cooling tower and parts. Our company's cooling tower products is being used widely around the world. Our business involve in Italy, Germany, Australia, UK, Indonesia, Thailand, Belgium, France, Poland, India, Malaysia, Singapore and New Zealand, etc..
Latino has a high quality team of talents. Team members are young and energetic, with a sense of innovation and the courage to meet the challenge.Team members develop and practice new e-marketing mode, follow consumer demand, provide customers with high quality products and services.
LATINO has an experienced team in quality and project implement to support the purchasing activities of overseas customers;The company's main products are cooling tower parts, such as Film Fill, drift eliminator and spray system, UPVC distribution pipes, FPR winding splash pipe, FRP profile parts,FRP gratings, Fan stack, band & clamp, etc.; Our product are approved by CTI and we have our own patent .
Our factory has the largest capacity and have been working with the recognized brands of cooling tower in around the world, our team have rich experience in oversea projects.we were your colleague, knowing your care, your culture and your requirements.So we make it easy for you to purchase high quality and good value internal plastic parts of cooling tower in China.
Our fill has been verified by actual operation for more than ten years. It is very reliable and efficient. You can rely on us to deliver a successful project while reducing your total project costs!
Q1. What's your Main Product ?
The company's main products are cooling tower and Cooling tower parts such as Film Fill, drift
eliminator and spray system, UPVC distribution pipes, FPR winding splash pipe, FRP profile parts,
FRP gratings, Fan stack, band & clamp, etc
Q2:How to define the product price?
A: PVC cooling Tower material is based on the thickness,vicat point, color, density,fire classification, packing and quantity.
Q3. Do you keep the stock of your products?
A: Yes, we maintain a certain amount of standard products inventory, in time to meet your needs.
Q4. Whether you have the ability to accept the product customization?
A: Products can be customized, we can make the new thermoforming or extruding mode based on your drawings and we can sign a confidentiality agreement about your patented product, pls contact us for any further information.
Q5: What's your delivery time ?
The delivery time normally will be 10 -30days , the specified delivery date will be according to customer request and order quantity .
Q6. How to reassure those who doubt the product quality and actual situations?
A professional system can ensure the whole latest development which will be monitored by you through the reports in the diffferent stages.
Q7.How about your after sale service?
1. Warranty service
a).Warranty: 1 year.
b) .Warranty starting: acceptance date.
2. Service commitment
Warranty period:
a). Our company will be responsible for the quality problems arising from the maintenance, replacement of parts and related materials.
b). Artificial damage will be repaired by our company, but the damaged devices shall be paid.
3. Expiration of the warranty period:
a). Our company provides lifelong maintenance, but the user is responsible for the cost of labor and material.
b). Our company also provides charging upgrades and improvements following to the customer's requirements.