FRP Winding Pipe Used For Cooling Tower Distribution

2021-06-02 14:36

FRP Winding Pipe Used For Cooling Tower Distribution


FRP widing pipe is glass fiber reinforced polyester filament winding pipe, It is made of fiberglass-reinforced material soaked with resin matrix that is winded on the core mould layer by layer according to the certain process, and finally its is done by condensing process. The GRP pipe wall is a kind of layer structure, its physical and chemical characteristics can be adjusted by changing the resin system or adopting different reinforcing material in order to suit different FRP pipe with various pressure level or with certain special characteristics made from different medium and working conditions.


Good physical mechanics performance
The density of the FRP pipe is usually about 1.8 to2.1g /cm3 ,which is a quarter of steel. And it is also higher than that of the cast iron and the plastic material. On one hand, the weight of the FRP pipe is usually not above that of the pipe with the same specification by one third, and It has good physical mechanics performance. On the other hand, the thermal expansion coefficient of the FRP pipe is generally corresponding to that of the steel, while its heat conduction coefficient is only 0.5% that of the steel. Thus it is a good thermal and electrical insulating material.


Being resistant to chemical erosion and longer service life
FRP is characterized with special ability to resist chemical erosion, so maybe it is the better choice for you by the different medium under the environment of full of pipe nets.It can be used about 50years.


Excellent hydraulic characteristics
Since the hydraulic characteristics is the important one for the FRP pipe, good hydraulic characteristics means the less losses of liquid pressure. If the pump with smaller diameter or with smaller power is chosen, the early investment for the pipe project will be reduced, and the electricity will also be used less. Hence the less operating cost.


Lower installation and keeping cost
The FRP pipe needs no special antiseptic treatment; the thermal layer could be thinner, even without thermal treatment; the pipe is lighter so that the lifting equipment only needs small tonnage and has smaller power consume; the single pipe is so long that is convenient for operating.
 


Standard: GBT 21238-2007,  ISO10639,  ASTM D 2996
Specification:
length: 1m---12m,
diameter: DN25---DN4000,
pressure: 0.1MPa---2.5MPa,
stiffness: 2500N/m2, 5000N/m2, 7500N/m2, 10000N/m2
jointing: spigot and socket jointing,  flange jointing,  butt and wrap joint, etc.


Packing: pallet or carton, it is convenient to load them into containers by forklift.


Cooling Tower

Cooling Tower Pipe

Relevant Cooling Tower Parts






Get the latest price? We'll respond as soon as possible(within 12 hours)
This field is required
This field is required
Required and valid email address
This field is required
This field is required
For a better browsing experience, we recommend that you use Chrome, Firefox, Safari and Edge browsers.